Cummins ISB6.7 CM2150 (2007-09) Fault Code: 442 PID: 168 SPN: 168 FMI: 0 Battery 1 Voltage – Data Valid but Above Normal Operational Range – Moderately Severe Level. ECM supply voltage is above the maximum system voltage level.
Share
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
This fault code is logged when the ECM battery supply voltage exceed 36-VDC. Causes of this fault code include:
1)Faulty alternator or regulator that is overcharging the system 2)Batteries connected in series instead of parallel
Possible repairs:
1)Install the battery system correctly. 2)Repair or replace the alternator, regulator, and/or the OEM wiring to the alternator.